Schneider Electric LR97D07M7 Electronic Overcurrent Relay, Tesys LR97D, 200 to 240VAC, 1.2 to 7A, 1C/O

TeSys LR97D electronic overcurrent relay, 7A/690V, to be supplied with 200-240V AC, for protection of motors with a rated current 1.2-6A. It provides 3 dials to adjust the protection, LOAD (1.2-7A) for the overcurrent level, O-TIME (0.3-10sec) for the acceptable duration of the overcurrent, D-TIME (0.5-30sec) for the starting duration. In addition, the device trips when the current is higher than 3 x LOAD during more than 0.5sec in steady state and if there is a missing phase during more than 3sec. Settings also include selectors for 1-phase/3-phase motors and manual/automatic reset, the device has a reset button, a test/stop button, 2 LED indicators (Run/Trip), 2 auxiliary contacts 1NO/NC for fault signaling. Settings can be locked by sealing the transparent cover. For direct attachment to the bottom terminals of a 3-phase contactor LC1D09-D38, with screw clamp terminals on bottom, the separate mounting from the contactor is possible using the terminal block LAD7B106 (to be ordered separately). Multi-standards certified (IEC, UL, CSA, CCC, EAC), compliant RoHs/Reach.

Main

  • Range: TeSys
  • Product name: TeSys D
  • Device short name: LR97
  • Product or component type: Electronic overcurrent relay
  • Relay application:
    • Sensitivity to phase failure
    • Locked rotor, mechanical jamming I > 3 x Isetting
    • Overload Imax > Isetting
  • Product compatibility: LC1D09...D38
  • Network type: AC
  • [Us] rated supply voltage: 200...240 V AC
  • Thermal protection adjustment range: 1.2…7 A
  • [Ue] rated operational voltage:
    • 600 V AC 50/60 Hz for power circuit (conforming to CSA)
    • 600 V AC 50/60 Hz for power circuit (conforming to UL)
    • 690 V AC 50/60 Hz for power circuit (conforming to IEC 60947-4-1)
  • Quantity per set: Set of 10

Complementary

  • Network frequency: 50...60 Hz
  • Mounting support:
    • Direct on contactor
    • Rail
  • Tripping threshold: 1.2...6 A
  • Surge withstand: 6 kV (conforming to IEC 61000-4-5)
  • Contacts type and composition: 1 C/O
  • [Ith] conventional free air thermal current: 3 A for control circuit
  • Protection type:
    • BS fuse 3 A for control circuit
    • GB2 circuit breaker 3 A for control circuit
    • GG fuse 3 A for control circuit
  • Maximum power:
    • 28 W at 110 V DC (conforming to IEC 60947)
    • 28 W at 220 V DC (conforming to IEC 60947)
    • 55 W at 24 V DC (conforming to IEC 60947)
    • 55 W at 48 V DC (conforming to IEC 60947)
    • 140 VA at 48 V AC (conforming to IEC 60947)
    • 360 VA at 110 V AC (conforming to IEC 60947)
    • 360 VA at 220 V AC (conforming to IEC 60947)
    • 70 VA at 24 V AC (conforming to IEC 60947)
  • [Ui] rated insulation voltage:
    • Power circuit: 600 V (conforming to CSA)
    • Power circuit: 600 V (conforming to UL)
    • Power circuit: 690 V (conforming to IEC 60947-4-1)
  • [Uimp] rated impulse withstand voltage: 6 kV
  • Phase failure sensitivity: < 3 s
  • Reset:
    • Automatic reset 120 s fixed
    • Electrical by interruption of power supply for minimum 0.1 s
    • Manual reset
  • Time range:
    • 0.2...10 s - O-time knob
    • 0.3...10 s - O-time knob
    • 0.5..30 s - D-time knob
  • Signalling function: 2 LEDs
  • Connections - terminals:
    • Control circuit: cable 1 x 1…25 mm² flexible with cable end
    • Control circuit: cable 1 x 1…25 mm² flexible without cable end
    • Power circuit: cable 1 x 1…4 mm² flexible with cable end
    • Power circuit: cable 1 x 1.5…10 mm² flexible without cable end
    • Power circuit: lug-clamp 1 x 1…4 mm² flexible with cable end
    • Power circuit: lug-clamp 1 x 1.5…10 mm² flexible without cable end
    • Control circuit: cable 2 x 1…25 mm² flexible with cable end
    • Control circuit: cable 2 x 1…25 mm² flexible without cable end
    • Control circuit: lug-clamp 1 x 1…25 mm² flexible with cable end
    • Control circuit: lug-clamp 1 x 1…25 mm² flexible without cable end
    • Control circuit: lug-clamp 2 x 1…25 mm² flexible with cable end
    • Control circuit: lug-clamp 2 x 1…25 mm² flexible without cable end
  • Tightening torque:
    • Control circuit: 0.6...1.2 N.m on lug-clamp
    • Power circuit: 2 N.m on cable
  • Height: 67.5 mm
  • Width: 45 mm
  • Depth: 67.5 mm
  • Net weight: 0.172 kg

Environment

  • Standards:
    • IEC 60947
    • IEC 60255-6
  • Product Certifications:
    • GOST
    • CSA
    • UL
  • Protective Treatment: TH (conforming to IEC 60068)
  • IP Degree of Protection: IP20 (conforming to IEC 60529)
  • Ambient Air Temperature:
    • For operation: -25…60 °C (conforming to IEC 60947-4-1)
    • For storage: -30…80 °C
  • Operating Altitude: 2000 m
  • Fire Resistance: 850 °C (conforming to IEC 60695-2-1)
  • Shock Resistance: 15 gn 11 ms (conforming to IEC 60068-2-7)
  • Vibration Resistance: 4 gn (conforming to IEC
S$ 133.30
(exc. GST)
S$ 145.30
(inc. GST)
Image
Lead time of 60 working days required.
Item will be ready to dispatch within the lead time specified.
Quantity:
/ EA
This item is sold by
Image
Schneider Electric
Highly Matched Items
View items that have the same or are a close match to the specifications of this item
Electronic Over Current Relays from SCHNEIDER ELECTRIC
Source & compare similar products
More from Electronic Over Current Relays
Expand your search with a wider selection
Recently Viewed Products
Compare & Refer to previously viewed items
Image
Top